Show simple item record

dc.contributor.authorAponte Luis, Juan
dc.contributor.authorRoa Romero, Laura M.
dc.contributor.authorGómez Galán, Juan Antonio 
dc.contributor.authorNaranjo Hernández, David
dc.contributor.authorEstudillo Valderrama, Miguel Ángel
dc.contributor.authorBarbarov Rostán, Gerardo
dc.contributor.authorRubia Marcos, Carlos
dc.date.accessioned2017-04-06T12:27:37Z
dc.date.available2017-04-06T12:27:37Z
dc.date.issued2014
dc.identifier.citationAponte Luis, J., Roa Romero, L.M., Gómez Galán, J.A., Naranjo Hernández, D., Estudillo Valderrama,M.A., Barbarov Rostán, G., Rubia Marcos, C.: "Design and implementation of a smart sensor for respiratory rate monitoring". Sensors. Vol. 14, págs. 3019-3032, (2014). DOI: 10.3390/s140203019en_US
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10272/13561
dc.description.abstractThis work presents the design, development and implementation of a smart sensor to monitor the respiratory rate. This sensor is aimed at overcoming the drawbacks of other systems currently available in market, namely, devices that are costly, uncomfortable, difficult-to-install, provide low detection sensitivity, and little-to-null patient-to-patient calibration. The device is based on capacitive sensing by means of an LC oscillator. Experimental results show that the sensor meets the necessary requirements, making feasible the proposed monitoring system with the technology used.en_US
dc.description.sponsorshipThis work has been supported by the Spanish Ministry of Science and Innovation, and FEDER funds under grant FPA2010-22131-C02-02, and by the Andalussian Innovation, Science and Enterprise Council, under grants P08-TIC-04069 and P10-TIC-6311.en_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subject.otherCapacitive technologyen_US
dc.subject.otherRespiratory rate monitoringen_US
dc.subject.otherSmart sensoren_US
dc.titleDesign and implementation of a smart sensor for respiratory rate monitoringen_US
dc.typeinfo:eu-repo/semantics/articleen_US
dc.identifier.doi10.3390/s140203019
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessen_US
dc.relation.projectIDinfo:eu-repo/grantAgreement/FEDER [FPA2010-22131-C02-02]en_US
dc.relation.projectIDinfo:eu-repo/grantAgreement/Andalussian Innovation, Science and Enterprise Council [P08-TIC-04069, P10-TIC-6311]


Files in this item

This item appears in the following Collection(s)

Show simple item record

Atribución-NoComercial-SinDerivadas 3.0 España
Except where otherwise noted, this item's license is described as Atribución-NoComercial-SinDerivadas 3.0 España

Copyright © 2008-2010. ARIAS MONTANO. Repositorio Institucional de la Universidad de Huelva
Contact Us | Send Feedback |